RF Corridor Wall

Manufacturer:

Design:

Construction

Single-glazed


Ceiling connection                                                                         Floor connection

Double-glazed


Ceiling connection                                                                         Floor connection

 

Technical details


 

Single-glazed

Double-glazed

Door optionally with hinged or sliding door only with hinged door
Sound protection up to 39dB (Rw) corresponds to 16mm LSG acoustic glass up to 49dB (Rw) corresponds to 12mm LSG acoustic glass
Glass elements 10, 12 and 16mm TSG or LSG acoustic glass 10mm, 12mm, in TSG or LSG acoustic glass.
Door elements Hinged door element: optionally at room height up to 300cm or with an over door panel up to 350cm.

Sliding door element: frameless, optionally at room height up to 300cm or with an over door panel up to 350cm.
Hinged door element: optionally at room height up to 300cm or with an over door panel up to 350cm.
Junctions
  • Post: to absorb tolerances and to connect to drywall.
  • 90° / 270° junction bevelled for corner formation.
  • Variable junction: bevelled for variable corner formation.
Connections T-connection, wall connection (solid wall or drywall) and facade connection. Open wall end: Variable glass edge.
Levelling Building tolerances and ceiling movement +27mm/-24mm
Flexibility Reversible Systemwand, einfachste Nachrüstung
Standard RF Corridor Wall Tested in accordance with ETAG 003 Standard.


You can find detailed technical information in the RF Corridor Wall brochure.

Award